Shandong Pinrui · Since 2012

One supplier for floor, wall and ceiling — built for hospitals.

We manufacture the panels and contract the installation, so one team owns the junctions between three surfaces normally split across three suppliers.

Request the specification pack See the test data
Class A / A2-S2,d0,t0 fire ratings NRC ≥ 0.90 to EN ISO 354 Antibacterial > 99.99% to GB/T 31402 60+ projects · ~70% healthcare
The package

Three surfaces, one contract, no arguments at handover.

Walls, ceilings and floors are usually bought separately, installed by three trades, then argued over: skirting lines that don't meet, grids that miss the wall joint, a floor finish incompatible with the wall base. Those are interface problems, not product problems.

Dingborui · ceilingsCeiling systems

  • GRP antibacterial ceiling panels
  • Glass-fibre acoustic ceiling panels
  • A2-S2,d0,t0 and Class A options
  • Demountable concealed grid

Taidixin · wallsWall systems

  • Medical clean & cleanroom panels
  • Glass-fibre resin panels
  • Class A non-combustible HPL
  • Metal composite & feature walls

Taidixin · floorsFloor systems

  • Homogeneous PVC vinyl
  • Cleanroom PVC, purified-carbon SPC
  • Rubber, RVT, linoleum
  • Sports flooring, outdoor WPC decking
Published data

Every number carries the standard it was tested to.

Where a report exists, we send the report — not the datasheet claim.

ProductParameterResultTest standard
Glass-fibre acoustic ceilingSound absorptionNRC ≥ 0.90EN ISO 354 / GB/T 20247
Glass-fibre acoustic ceilingFire classificationClass AEN 13501-1 / GB 8624
Glass-fibre acoustic ceilingAntibacterial (E. coli, S. aureus)> 99.99%GB/T 31402
Glass-fibre acoustic ceilingAnti-mouldGrade 0GJB 150.10A
GRP antibacterial ceilingFire classificationA2-S2,d0,t0EN 13501-1
GRP antibacterial ceilingWater absorption0.3%Manufacturer test
GRP antibacterial ceilingAntibacterial / anti-mould99.5% · class I / 0JIS Z 2801
Medical clean wall panelFire classificationClass AReport on request
Homogeneous PVC flooringFire / wear / slipB1 · Class T · R9Report on request
On certification, stated plainly: CE marking, SGS reports and Korean fire certification apply to our glass-fibre acoustic ceiling range only. The GRP and medical clean wall panel ranges ship with test reports, not with CE marking — and we say so before you specify.
Choosing between the two ceiling systems

Moisture or noise — that's the question.

GRP antibacterialGlass-fibre acousticMineral fibre (typical)Gypsum board (typical)
Primary driverMoisture, cleaningNoiseCostFlat finish
FireA2-S2,d0,t0Class AVariesBoard & framing vary
Sound absorptionNot the purposeNRC ≥ 0.90Moderate–goodLow
Water absorption0.3%Stable at RH 99Absorbs, sagsSoftens, crumbles
Antibacterial99.5%> 99.99%Coatings onlyNone inherent
DemountableYes, repeatedlyYesUsually single useNo

Most hospital projects take both: acoustic panels where speech privacy matters, GRP wherever cleaning is aggressive or humidity is uncontrolled.

Project record

60+ projects, roughly 70% of them medical.

Hospitals, maternity and children's facilities, mental health, rehabilitation and elder care — across Shandong (Jinan, Qingdao, Linyi, Weifang) and into Guizhou, Shanxi and Zhejiang.

A 1,200-bed tertiary teaching hospital in Shandong — 8,000 m² of wall, floor and ceiling delivered in 30 days, without closing a single ward. Client name withheld under our confidentiality policy; project reference available on request.

That project is why we sell the three surfaces together: phasing, night work and protecting a live ward are easier to hold when one contract owns all three.

How a project runs

Four steps, in writing.

01

Specification review

You send the BOQ or consultant spec; we return a room-by-room schedule with the test report behind each claim.

02

Sample & mock-up

Approval panels plus a mock-up bay, so junctions are signed off before production starts.

03

Production & packing

Cut to the setting-out drawing, labelled by room to match the installation sequence.

04

Installation

Our own teams on domestic contracts; elsewhere the project's contractor, working to our drawings and method statements.

FAQ

The four questions we're asked first.

Can you supply wall, ceiling and floor as one package?

Yes — that is the point of the company. One specification, one inspection, one delivery sequence, one party responsible for the junctions.

Which certificates can you actually send?

CE marking, SGS reports and Korean fire certification for the glass-fibre acoustic ceiling range; fire, acoustic, antibacterial and hazardous-substance reports for the rest. Where no report exists, we say so.

What is your MOQ and lead time?

Quoted per project, since both depend on panel types and mix. Send the area per surface and the specification, and we confirm in writing with the quotation.

Can I have samples before I specify?

Yes — tell us finish, thickness and room type, and we send panels including cut sections, so your team sees the build-up, not just the face.

Request the specification pack

Tell us the surfaces and the project.

We send datasheets, test reports and CAD details for the panel types in your specification. A named engineer replies within one working day.

Or email sales@pinruiflooring.com directly · WhatsApp available on request · We reply within one working day.