Chinese manufacturer of floor, wall and ceiling systems — since 2012 sales@pinruiflooring.com +86 175 6050 1246
C-02 DINGBORUI · Ceiling systems

Glass-fibre Acoustic Ceiling

NRC 0.90 sound absorption with Class A fire performance — the only range we supply with CE marking.

  • Samples available before approval — freight at buyer's account.
  • Test reports and technical documentation released per product.
  • FOB Qingdao or CIF to your destination port.
Fire classification
A (EN 13501-1+A1:2009 · GB 8624-2012)
Sound absorption
NRC ≥ 0.90 (EN ISO 354 · EN ISO 11654)
Antibacterial
99.99% to GB/T 31402-2015
Anti-mould
class 0 to GJB 150.10A-2009
Formaldehyde
≤ 0.124 mg/m³ to GB 6566

Overview

This is the range that carries the paperwork: CE marking, SGS reports and Korean fire certification, classified Class A to EN 13501-1 and tested to NRC ≥ 0.90 under EN ISO 354 / GB/T 20247. Antibacterial performance is above 99.99% to GB/T 31402 against E. coli and S. aureus, with anti-mould Grade 0 to GJB 150.10A.

It is specified where speech privacy and reverberation matter — inpatient wards, consulting rooms, imaging suites, teaching spaces — and it is stable at RH 99, which is why it also appears in humid service areas where acoustic mineral fibre would fail.

Ceilings are supplied with the concealed grid and perimeter trim, cut to the setting-out drawing.

Key properties

  • NRC ≥ 0.90 to EN ISO 354 / GB/T 20247
  • Class A to EN 13501-1, with CE marking, SGS and Korean fire certification
  • Antibacterial above 99.99% (GB/T 31402); anti-mould Grade 0 (GJB 150.10A)
  • Density 100–150 kg/m³; stable at RH 99
  • Cuts air-conditioning load — measured at roughly two-thirds of the baseline

Full specification

Fire classificationA (EN 13501-1+A1:2009 · GB 8624-2012)
Sound absorptionNRC ≥ 0.90 (EN ISO 354 · EN ISO 11654)
Antibacterial99.99% to GB/T 31402-2015
Anti-mouldclass 0 to GJB 150.10A-2009
Formaldehyde≤ 0.124 mg/m³ to GB 6566

Values are the manufacturer's tested figures. Where a figure is marked "report on request", the test report is released against a project reference.

Where it is specified

  • Inpatient wards
  • Consulting and treatment rooms
  • Imaging suites
  • Lecture theatres
  • Open-plan offices
  • Restaurants and hospitality

FAQ

Can I get samples before specifying?

Yes — tell us finish and thickness and we send panels including cut sections, so your team sees the build-up rather than only the face.

Which documents come with the panel?

Fire, acoustic, antibacterial or hazardous-substance reports as applicable, plus the installation method statement. CE marking applies to our glass-fibre acoustic ceiling range only.

What is the minimum order and lead time?

Quoted per project, since both depend on panel types and mix. Send the area and the specification and we confirm in writing with the quotation.

Send the project and we will answer line by line

Including the lines we cannot meet — that is faster than finding out after the order.

Request a quote